AC evaporator coil frozen: why it happens and the thaw protocol
A frozen indoor coil means either poor airflow (filter, blower) or low refrigerant (leak). The fix protocol matters: thaw completely before a tech arrives, or the diagnosis will be wrong.
What to do, in order
- Switch thermostat to OFF, fan to ON — airflow-only mode melts the coil without cooling it further. Expect 3–8 hours and possibly water around the air handler (towels/pan).
- Replace the filter while it thaws.
- After full thaw, restart in COOL with a new filter. If it cools normally: airflow was the culprit — check the blower wheel and duct returns next.
- If it ices again within hours: refrigerant is low (leak) or the blower is failing. Tech visit — ask for electronic leak detection, not a blind recharge.
- Water damage check: insulation around the coil and the pan/drain — refreeze cycles crack pans.
Red flags — stop and call a pro
- Ice on the outdoor unit's lines too — system-wide refrigerant issue; running it slugs the compressor, shut it off
- Mold smell after multiple freeze/thaw events — wet insulation in the air handler
- Water dripping through the ceiling below an attic air handler — pan overflow, act fast
Prevention
Filter every 60–90 days, keep returns unblocked, and recharge only with leak repair — repeat freezing means nobody fixed the leak.
This guide is maintained by the ee.ltd editorial team — reviewed for 2026. Browse all home repair guides or compare hvac costs.
Related guides
- AC running but not cooling: 6 checks before you call
- Furnace short cycling (starts and stops every few minutes)
- Thermostat not working: dead screen, wrong temps, no response
- AC won't turn on: what to check before you call
What this repair typically costs
Get free quotes
Licensed hvac pros in your city — quotes are free, response is fast.